FP303 : PC Polishing, Our Way of Doing to Prevent PCO to the Maximum Extent, Prospective Study of 30 cases

Dr. Prabhakara Sastry Papaganti, P07791, Dr. V. M. V. R. V. Prasada Rao, Dr. Jemi Sandhyavali Lam, Dr. Ramesh Kumar Golkonda Satyaprakasam

We have followed a special way of polishing posterior capsule to prevent posterior capsule opacification in 30 eyes (Prospective Study).This procedure consists of using slightly roughened posterior surface of simcoe cannula, 3-5 mm near the tip, to polish the capsular bag after complete removal of nucleus & cortex etc…, plenty of viscomet is used to balloon out the bag at starting of polishing. P.C. is rubbed, polished with this special cannula slowly for 2-3 mints central 5-6 mm of P.C. is cleaned in a circular fashion and sweeping strokes are used in the four corners of the bag. B.S.S. flow rate is kept at zero level during polishing. 5ml of B.S.S. mixed with 2-3 drops each of moxiflox and triamcilone are used to irrigate the bag. Again bag is cleaned with only B.S.S.
Result:
We have followed all these cases for 1 yr and all of them did not develop P.C.O. All these case got BCVA of 6/6 P, long term results are yet to be studied is large no of cases.

 